Home › Guides › Linear guides › TM03NLS

TM03NLS Miniature Linear Guide Dimensions and Load Ratings

TM03NLS miniature linear guide: dynamic load C=0.353 kN, static load C0=0.587 kN, allowable moment Mx=0.94 N·m, block weight 1.6 g, rail weight 0.053 kg/m, Stainless steel.

TM stainless, standardStainless steelStandard rail widthLong blockSize 3

Identification

GroupTM stainless, standard
MaterialStainless steel
Rail widthStandard rail width
Block typeLong block
Size3
Rail width W13 mm
Rail height H12.6 mm
Mounting hole P10 mm
Catalogue pageA135

Load ratings and allowable moments

ItemValueDescription
C0.353 kNBasic dynamic load rating
C00.587 kNBasic static load rating
Mx0.94 N·mAllowable moment, rolling
My0.98 N·mAllowable moment, pitching — single
My5.6 N·mAllowable moment, pitching — two blocks
Mz1.2 N·mAllowable moment, yawing — single
Mz6.7 N·mAllowable moment, yawing — two blocks

Weights

ItemValue
Block weight1.6 g
Rail weight (per metre)0.053 kg/m

TM uses kN and N·m; the TR/SR series uses kgf and kg·mm.

Other variants of this size

FAQ

Are the load units for TM03NLS the same as the TR series?
No. The TM miniature series states basic load ratings in kN and allowable moments in N·m, while the TR/SR series uses kgf and kg·mm. Convert before comparing (1 kgf ≈ 9.81 N).
How do I choose between the stainless and carbon steel types?
The last letter is S for stainless and A for carbon (alloy) steel. Choose S for semiconductor, food and medical applications where corrosion resistance and cleanliness matter; A is more economical for general automation. Dimensions and load ratings are identical.
How long can TM rails be?
Lengths beyond 1300 mm are made up of two or more rails butted together — confirm the butt-joint accuracy and support method with the maker. Accuracy is N / H / P; clearance is ZF / Z0 / Z1.

Related Technical Guides

Load and moment data from the MOSIONX 2026 general catalogue, chapter A page A135. Note the TM series uses kN and N·m.

Request a QuoteOpen Selector →Selection Guide